Trip Modules, Brake Monitors, Conveyor Monitors– PTS / PTD / PTD-BRK / PAM

The PTS-VC-XX is a fully isolated trip amplifier/alarm module that accepts either a voltage or current input signal and provides a single (1) independently adjustable trip relay output.

The PTS-VC-XX can be used as a standalone alarm unit for high or low level alarms. The relay can be field set by the use of internal links for high or low and energized or deenergised. The relay has its own dead band adjustment which can be set from between 0 – 60% of input signal.

The PTD-VC-XX is a fully isolated trip amplifier/alarm module that accepts either a voltage or current input signal and provides two (2) independently adjustable trip relays output.

The PTD-VC-XX can be used as a standalone alarm unit for high or low level alarms. The relays can be field set by the use of internal links for high or low and energized or deenergised. The relays have their own dead band adjustment which can be set from between 0 – 60% of input signal.

The PTD-BRK/FS is a fully isolated dual trip amplifier/alarm module that accepts an AC or DC current input from 0 Amp up to 2 Amps from up to a 415V supply line.

The PTD-BRK/FS provides a trip relay output which operates between the fixed “Base” and “Maximum” current setting. It works as a stand-alone alarm unit and operates as a window comparator where the relay de-energises if the signal goes below 50mA or above 500mA. The relay has a fixed dead-band of 20%.

The PTD-BRK/FF-3A is a fully isolated dual trip amplifier/alarm module that accepts an AC/DC current input from 0 Amp up to 3 Amps from up to a 415V supply line. The PTD-BRK/FF-3A provides an adjustable trip relay output. The relay is normally energised and trips on both Hi and Lo alarm conditions. The ‘Base’ current is set by two front panel adjustment switches with the standard unit having set points fixed at +50% and -50% of the Base current.

The PTD-BRK/FF-3A is a stand-alone alarm unit and operates as a window comparator where the relay de-energises if the signal goes outside either the Lo or Hi settings. The relay has a fixed dead-band of 20%.

PTS / PTD

  • Special 24VDC supply level
  • Output current to 3Amps (fused)
  • Externally accessible set points
  • System healthy indication
  • Voltage healthy indication
  • Current healthy indication
  • OFF time delay (factory set)
  • Fail safe system
  • Very small footprint area

PTD-BRK

  • Wide operating voltage range
  • Set point trip status LED’s
  • Trip window set by the 2 front panel selector switches and status LED’s
  • Very small footprint area
  • DIN & G rail mounting style
  • Low power consumption
  • 600V HBC 3.15A input protection fuse

PTS / PTD

  • Power Supply: 12Vdc, 24Vdc or 48Vdc
  • VA Rating: Typically 1.0VA
  • Max Power: Typically 1.5 VA (relay energised)
  • Input – Standard Ranges
  • Volts: 0-10 Vdc
  • Current: 4-20 mA
  • Amps dc: 0 – 3 Amps dc
  • Input Resistance: 0.03R
  • Other ranges upon request
  • Output (one c/o relay): 1 Relay c/o contact

PTD-BRK

  • Nominal Supply: 22V – 60Vac/dc
  • VA Rating: Typically 1.2VA
  • Max Power: Typically 1.3VA with relay energised.
  • Input (Internally Fuse Protected 3.15A SIBA 189-020)
  • Amps AC or DC: 0 Amp to 1Amps (Terms 1-3) / 0 Amp to 2Amps (Terms 1-2)
  • Base Current (1A): 50mA to 500mA
  • Base Current (2A): 120mA to 1000mA
  • Volts (max): 500Vac/300Vdc on terms 1 & 3
  • Input Resistance: < 0.1 Ohm
  • Output (Single relay c/o output)
  • Set Point: Relay c/o contact, Under Current and/or Over, Current fixed set points.
  • For 0 – 1Amp: 0– 10Vdc (1A = 10V)
  • For 0 – 3Amp: 0 – 7.5Vdc (limited span)